J’ai voulu changer un disque du RAID : un SAS « DELL 900 GB ST900MM0006 » par un SATA « KINGSTON SA400S37960G A To »
Mais il n’y a pas de reconstruction …
Information du RAID :
# megacli -ldinfo -lALL -aALL
Adapter 0 -- Virtual Drive Information:
Virtual Drive: 0 (Target Id: 0)
Name :900GbRd5
RAID Level : Primary-5, Secondary-0, RAID Level Qualifier-3
Size : 4.089 TB
Sector Size : 512
Parity Size : 837.75 GB
State : Degraded
Strip Size : 64 KB
Number Of Drives : 6
Span Depth : 1
Default Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy : Disk's Default
Encryption Type : None
Default Power Savings Policy: Controller Defined
Current Power Savings Policy: None
Can spin up in 1 minute: Yes
LD has drives that support T10 power conditions: Yes
LD's IO profile supports MAX power savings with cached writes: No
Bad Blocks Exist: No
Is VD Cached: Yes
Cache Cade Type : Read Only
Virtual Drive: 1 (Target Id: 1)
Name :2TbRd1iw
RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0
Size : 1.818 TB
Sector Size : 512
Mirror Data : 1.818 TB
State : Optimal
Strip Size : 64 KB
Number Of Drives : 2
Span Depth : 1
Default Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy : Disk's Default
Encryption Type : None
Default Power Savings Policy: Controller Defined
Current Power Savings Policy: None
Can spin up in 1 minute: Yes
LD has drives that support T10 power conditions: No
LD's IO profile supports MAX power savings with cached writes: No
Bad Blocks Exist: No
Is VD Cached: Yes
Cache Cade Type : Read Only
Exit Code: 0x00
# perccli64 /c0 /eall /sall show
CLI Version = 007.0529.0000.0000 Sep 18, 2018
Operating system = Linux 6.8.12-5-pve
Controller = 0
Status = Success
Description = Show Drive Information Succeeded.
Drive Information :
=================
----------------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type
----------------------------------------------------------------------------------
32:0 0 Onln 0 837.75 GB SAS HDD N N 512B ST900MM0006 U -
32:1 1 GHS - 893.75 GB SATA SSD N N 512B KINGSTON SA400S37960G U -
32:2 2 Onln 0 837.75 GB SAS HDD N N 512B ST900MM0006 U -
32:3 3 Onln 1 1.818 TB SATA HDD N N 512B ST2000VN003-3CW102 U -
32:4 4 Onln 0 837.75 GB SAS HDD N N 512B ST900MM0006 U -
32:5 5 Onln 0 837.75 GB SAS HDD N N 512B ST900MM0006 U -
32:6 6 Onln 0 837.75 GB SAS HDD N N 512B ST900MM0006 U -
32:7 7 Onln 1 1.818 TB SATA HDD N N 512B ST2000VN003-3CW102 U -
----------------------------------------------------------------------------------
EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
Med-Media Type|SED-Self Encrypting Drive|PI-Protection Info
SeSz-Sector Size|Sp-Spun|U-Up|D-Down/PowerSave|T-Transition|F-Foreign
UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded
# megacli -PDList -aAll
Adapter #0
Enclosure Device ID: 32
Slot Number: 0
Drive's position: DiskGroup: 0, Span: 0, Arm: 0
Enclosure position: 1
Device Id: 0
WWN: 5000C5007E266648
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
Raw Size: 838.362 GB [0x68cb9e30 Sectors]
Non Coerced Size: 837.862 GB [0x68bb9e30 Sectors]
Coerced Size: 837.75 GB [0x68b80000 Sectors]
Sector Size: 0
Firmware state: Online, Spun Up
Device Firmware Level: LS0C
Shield Counter: 0
Successful diagnostics completion on : N/A
SAS Address(0): 0x5000c5007e266649
SAS Address(1): 0x0
Connected Port Number: 2(path0)
Inquiry Data: SEAGATE ST900MM0006 LS0CS0N2SHEW
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive Temperature :25C (77.00 F)
PI Eligibility: No
Drive is formatted for PI information: No
PI: No PI
Port-0 :
Port status: Active
Port's Linkspeed: 6.0Gb/s
Port-1 :
Port status: Active
Port's Linkspeed: Unknown
Drive has flagged a S.M.A.R.T alert : No
Enclosure Device ID: 32
Slot Number: 1
Enclosure position: 1
Device Id: 1
WWN: 50026b7785868c60
Sequence Number: 10
Media Error Count: 0
Other Error Count: 150
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SATA
Hotspare Information:
Type: Global, is revertible
Raw Size: 894.252 GB [0x6fc81ab0 Sectors]
Non Coerced Size: 893.752 GB [0x6fb81ab0 Sectors]
Coerced Size: 893.75 GB [0x6fb80000 Sectors]
Sector Size: 0
Firmware state: Hotspare, Spun Up
Device Firmware Level: 70.5
Shield Counter: 0
Successful diagnostics completion on : N/A
SAS Address(0): 0x4433221106000000
Connected Port Number: 1(path0)
Inquiry Data: 50026B7785868C60 KINGSTON SA400S37960G SHFK70.5
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Solid State Device
Drive: Not Certified
Drive Temperature : N/A
PI Eligibility: No
Drive is formatted for PI information: No
PI: No PI
Drive's NCQ setting : N/A
Port-0 :
Port status: Active
Port's Linkspeed: 6.0Gb/s
Drive has flagged a S.M.A.R.T alert : No
Enclosure Device ID: 32
Slot Number: 2
Drive's position: DiskGroup: 0, Span: 0, Arm: 2
Enclosure position: 1
Device Id: 2
WWN: 5000C5007F6CEAE4
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
Raw Size: 838.362 GB [0x68cb9e30 Sectors]
Non Coerced Size: 837.862 GB [0x68bb9e30 Sectors]
Coerced Size: 837.75 GB [0x68b80000 Sectors]
Sector Size: 0
Firmware state: Online, Spun Up
Device Firmware Level: LS0C
Shield Counter: 0
Successful diagnostics completion on : N/A
SAS Address(0): 0x5000c5007f6ceae5
SAS Address(1): 0x0
Connected Port Number: 3(path0)
Inquiry Data: SEAGATE ST900MM0006 LS0CS0N3AYB9
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive Temperature :24C (75.20 F)
PI Eligibility: No
Drive is formatted for PI information: No
PI: No PI
Port-0 :
Port status: Active
Port's Linkspeed: 6.0Gb/s
Port-1 :
Port status: Active
Port's Linkspeed: Unknown
Drive has flagged a S.M.A.R.T alert : No
Enclosure Device ID: 32
Slot Number: 3
Drive's position: DiskGroup: 1, Span: 0, Arm: 0
Enclosure position: 1
Device Id: 3
WWN: 5000c500e76415ef
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SATA
Raw Size: 1.819 TB [0xe8e088b0 Sectors]
Non Coerced Size: 1.818 TB [0xe8d088b0 Sectors]
Coerced Size: 1.818 TB [0xe8d00000 Sectors]
Sector Size: 0
Firmware state: Online, Spun Up
Device Firmware Level: SC60
Shield Counter: 0
Successful diagnostics completion on : N/A
SAS Address(0): 0x4433221104000000
Connected Port Number: 4(path0)
Inquiry Data: ZWD0FNZ4ST2000VN003-3CW102 SC60
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive: Not Certified
Drive Temperature :22C (71.60 F)
PI Eligibility: No
Drive is formatted for PI information: No
PI: No PI
Drive's NCQ setting : N/A
Port-0 :
Port status: Active
Port's Linkspeed: 6.0Gb/s
Drive has flagged a S.M.A.R.T alert : No
Enclosure Device ID: 32
Slot Number: 4
Drive's position: DiskGroup: 0, Span: 0, Arm: 3
Enclosure position: 1
Device Id: 4
WWN: 5000C5007F21B7B8
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
Raw Size: 838.362 GB [0x68cb9e30 Sectors]
Non Coerced Size: 837.862 GB [0x68bb9e30 Sectors]
Coerced Size: 837.75 GB [0x68b80000 Sectors]
Sector Size: 0
Firmware state: Online, Spun Up
Device Firmware Level: LS0C
Shield Counter: 0
Successful diagnostics completion on : N/A
SAS Address(0): 0x5000c5007f21b7b9
SAS Address(1): 0x0
Connected Port Number: 7(path0)
Inquiry Data: SEAGATE ST900MM0006 LS0CS0N3553B
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive Temperature :26C (78.80 F)
PI Eligibility: No
Drive is formatted for PI information: No
PI: No PI
Port-0 :
Port status: Active
Port's Linkspeed: 6.0Gb/s
Port-1 :
Port status: Active
Port's Linkspeed: Unknown
Drive has flagged a S.M.A.R.T alert : No
Enclosure Device ID: 32
Slot Number: 5
Drive's position: DiskGroup: 0, Span: 0, Arm: 4
Enclosure position: 1
Device Id: 5
WWN: 5000C5007F212928
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
Raw Size: 838.362 GB [0x68cb9e30 Sectors]
Non Coerced Size: 837.862 GB [0x68bb9e30 Sectors]
Coerced Size: 837.75 GB [0x68b80000 Sectors]
Sector Size: 0
Firmware state: Online, Spun Up
Device Firmware Level: LS0C
Shield Counter: 0
Successful diagnostics completion on : N/A
SAS Address(0): 0x5000c5007f212929
SAS Address(1): 0x0
Connected Port Number: 6(path0)
Inquiry Data: SEAGATE ST900MM0006 LS0CS0N357QD
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive Temperature :24C (75.20 F)
PI Eligibility: No
Drive is formatted for PI information: No
PI: No PI
Port-0 :
Port status: Active
Port's Linkspeed: 6.0Gb/s
Port-1 :
Port status: Active
Port's Linkspeed: Unknown
Drive has flagged a S.M.A.R.T alert : No
Enclosure Device ID: 32
Slot Number: 6
Drive's position: DiskGroup: 0, Span: 0, Arm: 5
Enclosure position: 1
Device Id: 6
WWN: 5000C5007F21A7A4
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
Raw Size: 838.362 GB [0x68cb9e30 Sectors]
Non Coerced Size: 837.862 GB [0x68bb9e30 Sectors]
Coerced Size: 837.75 GB [0x68b80000 Sectors]
Sector Size: 0
Firmware state: Online, Spun Up
Device Firmware Level: LS0C
Shield Counter: 0
Successful diagnostics completion on : N/A
SAS Address(0): 0x5000c5007f21a7a5
SAS Address(1): 0x0
Connected Port Number: 5(path0)
Inquiry Data: SEAGATE ST900MM0006 LS0CS0N355D8
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive Temperature :24C (75.20 F)
PI Eligibility: No
Drive is formatted for PI information: No
PI: No PI
Port-0 :
Port status: Active
Port's Linkspeed: 6.0Gb/s
Port-1 :
Port status: Active
Port's Linkspeed: Unknown
Drive has flagged a S.M.A.R.T alert : No
Enclosure Device ID: 32
Slot Number: 7
Drive's position: DiskGroup: 1, Span: 0, Arm: 1
Enclosure position: 1
Device Id: 7
WWN: 5000c500e7641717
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SATA
Raw Size: 1.819 TB [0xe8e088b0 Sectors]
Non Coerced Size: 1.818 TB [0xe8d088b0 Sectors]
Coerced Size: 1.818 TB [0xe8d00000 Sectors]
Sector Size: 0
Firmware state: Online, Spun Up
Device Firmware Level: SC60
Shield Counter: 0
Successful diagnostics completion on : N/A
SAS Address(0): 0x4433221100000000
Connected Port Number: 0(path0)
Inquiry Data: ZWD0FP6VST2000VN003-3CW102 SC60
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive: Not Certified
Drive Temperature :22C (71.60 F)
PI Eligibility: No
Drive is formatted for PI information: No
PI: No PI
Drive's NCQ setting : N/A
Port-0 :
Port status: Active
Port's Linkspeed: 6.0Gb/s
Drive has flagged a S.M.A.R.T alert : No
Exit Code: 0x00
# megacli -PdGetMissing -a0
Adapter 0 - Missing Physical drives
No. Array Row Size Expected
0 0 1 857856 MB
Exit Code: 0x00
J’ai mis le disque en HotSpare pour que le Rebuild se fasse :
# megacli -PDHSP -Set -PhysDrv [32:1] -a0
Adapter: 0: Set Physical Drive at EnclId-32 SlotId-1 as Hot Spare Success.
Exit Code: 0x00
Impossible de forcer le ReBuild :
# megacli -PDRbld -Start PhysDrv[32:1] -a0
Cannot Rebuild Physical Drive at Enclosure - 32, Slot - 1.
FW error description:
The specified device is in a state that doesn't support the requested command.
Exit Code: 0x32
Export des logs
# megacli -AdpEventLog -GetEvents -f /root/raid.log -aALL
Dans les logs
Time: Sun Jan 19 07:29:35 2025
Code: 0x00000071
Class: 0
Locale: 0x02
Event Description: Unexpected sense: PD 01(e0x20/s1) Path 4433221106000000, CDB: 4d 00 46 00 00 00 00 00 04 00, Sense: 5/24/00
Event Data:
===========
Device ID: 1
Enclosure Index: 32
Slot Number: 1
CDB Length: 10
CDB Data:
004d 0000 0046 0000 0000 0000 0000 0000 0004 0000 0000 0000 0000 0000 0000 0000 Sense Length: 18
Sense Data:
0070 0000 0005 0000 0000 0000 0000 000a 0000 0000 0000 0000 0024 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
Visiblement il manque une information :
# megacli -PdReplaceMissing -PhysDrv[32:1] -Array0 -row1 -a0
Adapter: 0: Failed to replace Missing PD at Array 0, Row 1.
FW error description:
The specified device is in a state that doesn't support the requested command.
Exit Code: 0x32
# megacli -PDHSP -Rmv -PhysDrv [32:1] -a0
Adapter: 0: Remove Physical Drive at EnclId-32 SlotId-1 as Hot Spare Success.
Exit Code: 0x00
# megacli -PdReplaceMissing -PhysDrv[32:1] -Array0 -row1 -a0
Adapter: 0: Failed to replace Missing PD at Array 0, Row 1.
FW error description:
The specified physical drive does not have the appropriate attributes to complete the requested command.
Exit Code: 0x26
# megacli -CfgForeign -Scan -a0
There is no foreign configuration on controller 0.
Exit Code: 0x00
# megacli -PDMakeGood -PhysDrv [32:1] -Force -a0
Adapter: 0: Failed to change PD state at EnclId-32 SlotId-1.
Exit Code: 0x01
Quand je regarde la doc : Exit Code: 0x26, which means « Unable to use SATA(SAS) drive to replace SAS(SATA) ». Voir ici : https://www.thomas-krenn.com/de/wiki/MegaCLI_Error_Messages
A suivre.
J’aime ça :
J’aime chargement…